Product Features & specs :

Generac QT10068KVAC Liquid-Cooled 6.8L 100kW 277/480V 3-Phase Propane Aluminum Commercial Generator (CARB)

Details

Generac makes it easy and cost effective to configure the exact backup power system your home or business requires. A standby generator often pays for itself in just one power outage by keeping the security system running, large appliances operating and providing a safe haven for your family or customers in an emergency.

Premium features are standard on the ultimate standby generator. A low speed, super quiet, liquid-cooled engine, provides greater fuel efficiency and a longer life for the most environmentally friendly unit on the market. Ideal for larger commercial applications.

Features:

  • Liquid-cooled engine

  • Solid state frequency compensated digital voltage regulator

  • Clean burning and highly reliable continuous fuel source

  • Super silent neighbor-friendly Quiet-Test mode for a weekly self diagnostic exercise

  • Aluminum, all-weather enclosure prolongs the life of your generator with corrosion resistant protection from the elements, making it ideal for salt-air coastal climates

  • Hour meter monitors run time between maintenance sessions

  • PowerManager H-100 Controller integrates control of the genset, governor and voltage regulator via a single, 32-bit digital microprocessor which simultaneously monitors key parameters and user-defined inputs/outputs

  • Dynamic and static battery charger

  • High flow low noise factory engineered exhaust system

  • Watertight electrical connectors

  • Rodent proof construction

  • All components easily accessible for maintenance

  • Requires compatible Generac RTS model transfer switch, sold separately

  • Good Housekeeping Seal of Approval

  • CARB compliant for use in California

What’s Included:

  • Oil Drain Extension

  • Radiator Drain Extension

  • Battery Charge Alternator

  • 2 Amp Static Battery Charger

  • Battery Cables and Rack

  • Flex Fuel Line

  • Fan and Belt Guards

  • Instruction Sheets

Power Source

Gas

Fuel Consumption at 50% Load (Natural Gas)

713 cu-ft/hr

Engine Make

Generac

Engine Speed (RPM)

3600

Fuel Consumption at 100% Load (Natural Gas)

1260 cu-ft/hr

Fuel Consumption at 100% Load (LP Vapor)

13.9 gal/hr

Amprage (LP Vapor)

150

Transfer Switch Included

No

Engine Model

V-Type

Rated Watts (LP Vapor)

100000 Watts

Cooling System

Liquid-Cooled

Rated Watts (Natural Gas)

94000

Max Wattage

100000

Fuel Type

Gasoline/Liquid Propane

Motor Phase

3

Voltage Regulation

Yes

CARB Compliant

Yes

Enclosure Type

Aluminum

Alternator Type

Brushless

Fuel Consumption at 50% Load (LP Vapor)

7.9 gal/hr

Noise Rating (dBA)

72

Length

116 in.

Width

37 in.

Height

55 in.

Depth

55 in.

Weight

2531 lbs.

Warranty Term

2 Year

Reviews :

Q & A :

Warranty:

GENERAC POWER SYSTEMS STANDARD LIMITED WARRANTY FOR COMMERCIAL PRODUCT 50kW AND ABOVE

 

For a period of two (2) years from the date of sale, Generac Power Systems, Inc. will, at its option, repair or replace any part(s) which, upon examination, inspection, and testing by Generac Power Systems or an Authorized/Certified Generac Power Systems Dealer, or branch thereof, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Authorized/ Certified Generac Power Systems Dealer, or branch thereof.

 

This warranty applies only to Generac Power Systems Generators used in "Standby" applications, as Generac Power Systems, Inc. has defined Standby, provided said generator has been properly installed and inspected on-site by appropriate personnel. Scheduled maintenance, as outlined by the generator owner's manual, is highly recommended. This should be performed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. This will verify service has been performed on the unit throughout the warranty period.

 

WARRANTY SCHEDULE

YEARS ONE and TWO

Limited comprehensive coverage on mileage, labor, and parts listed.

 

ALL COMPONENTS

* Start-up and/or On-line Registration, or Registration Card, along with Proof of Purchase, must be performed and/or sent in.

 

Guidelines:

  • Any and all warranty repairs and/or concerns, must be performed and/or addressed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof.
  • A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the genset. If a Non - Generac Power Systems, Inc. Transfer Switch is substituted for use and directly causes damage to the genset, no warranty coverage shall apply.
  • All warranty expense allowances are subject to the conditions defined in Generac Power Systems Warranty, Policies, and Procedures Flat Rate Manual.
  • Units that have been resold are not covered under the Generac Power Systems Warranty, as this Warranty is not transferable.
  • Unit enclosure is only covered against rust or corrosion the first year of the warranty provision.
  • Use of Non-Generac replacement part(s) will void the warranty in its entirety.
  • Engine coolant heaters (block-heaters), heater controls and circulating pumps are only covered during the first year of the warranty provision (If applicable).

    • THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:
      • 1. Any unit built/manufactured prior to January 1, 2005.
      • 2. Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up).
      • 3. Any failure caused by contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oils or coolants/antifreeze.
      • 4. Units sold, rated or used for "Prime Power", "Trailer Mounted" or "Rental Unit" applications as Generac Power Systems have defined Prime Power, Trailer Mounted or Rental Unit. Contact a Generac Power Systems Distributor for Prime Power, Trailer Mounted or Rental Unit definition and warranty.
      • 5. Units used for prime power in place of existing utility power where utility is present or in place of utility power where utility power service does not normally exist.
      • 6. Failures caused by any external cause or act of God such as, but not limited to, collision, fire, theft, freezing, vandalism, riot or wars, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado, hurricane, terrorist acts or nuclear holocaust.
      • 7. Products that are modified or altered in a manner not authorized by Generac Power Systems in writing.
      • 8. Failures due, but not limited to, normal wear and tear, accident, misuse, abuse, negligence, or improper installation or sizing.
      • 9. Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).
      • 10. Failure due to misapplication, misrepresentation, or bi-fuel conversion.
      • 11. Telephone, facsimile, cell phone, satellite, internet, or any other communication expenses.
      • 12. Rental equipment used while warranty repairs are being performed (i.e. rental generators, cranes, etc.).
      • 13. Overtime, holiday, or emergency labor.
      • 14. Planes, ferries, railroad, busses, helicopters, snowmobiles, snow-cats, off-road vehicle or any other mode of transportation deemed abnormal.
      • 15. Any and all expenses incurred investigating performance complaints unless defective Generac materials and/or workmanship were the direct cause of the problem.
      • 16. Starting batteries, fuses, light bulbs, engine fluids, and overnight freight cost for replacement part(s).

       

      THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, SPECIFICALLY, GENERAC POWER SYSTEMS MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

       

      Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to purchaser/owner.

       

      GENERAC POWER SYSTEMS ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC POWER SYSTEMS BE LIABLE FOR ANY INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC POWER SYSTEMS, INC. NEGLIGENCE.

       

      Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to purchaser/ owner. Purchaser/owner agrees to make no claims against Generac Power Systems, Inc. based on negligence. This warranty gives purchaser/owner specific legal rights. Purchaser/owner also may have other rights that vary from state to state.